Recall Detail

LEXUS / RX300 / 1999

Components - Details
NHTSA Record Id: 11827 Vehicale/Equipment Name: LEXUS
Recalled Component Id: 000008975000079863000000074 Manufacturer Supplied Component Name:
Model Name: RX300 Model Year: 1999
NHTSA Campaign Number: 99V012000 Mfr Campaign Number: XL-2
Component Name: SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DIFFERENTIAL PROPORTIONAL VALVE Manufacturer That Filed Report: TOYOTA MOTOR CO., LTD.
Start date of Manufacturing: Jan, 24 1998 End date of Manufacturing: Dec, 17 1998
Report For : V Potential Number Of Unit Affected: 6503
Date Owner Notified By MFR : Feb, 16 1999 Recall Initiator: MFR
Manufacturers Of recalled Vehicles/Products : Toyota Motor Corporation Report Received Date: Jan, 20 1999
Record Creation date : Jan, 28 1999 Federal Motar Safety Number:
Defect Summary : Vehicle description: passenger vehicles equipped with the optional traction control system. due to improper design of the rear brake tube distribution, if one of the dual brake lines fails when the driver applies the brake, the vehicle will feel unstable compared to vehicles with proper rear brake tube distribution. Consequence Summary: This condition can increase the risk of a crash.
Corrective Summary : Dealers will install modified brake tubes. Recall Notes: Owner notification began february 16, 1999.owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact toyota at 1-800-331-4331.also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236).
Manufacturer Supplied Component Description: Manufacturer Supplied Component Part Number: