Recall Detail

ORION / VI / 1998

Components - Details
NHTSA Record Id: 13352 Vehicale/Equipment Name: ORION
Recalled Component Id: 000008744000078425000000012 Manufacturer Supplied Component Name:
Model Name: VI Model Year: 1998
NHTSA Campaign Number: 98V175000 Mfr Campaign Number:
Component Name: STEERING:HYDRAULIC POWER ASSIST:PUMP Manufacturer That Filed Report: ORION BUS INDUSTRIES, INC.
Start date of Manufacturing: May, 19 1998 End date of Manufacturing: Jul, 21 1998
Report For : V Potential Number Of Unit Affected: 52
Date Owner Notified By MFR : Jul, 24 1998 Recall Initiator: MFR
Manufacturers Of recalled Vehicles/Products : Daimler Commercial Buses NA Report Received Date: Jul, 31 1998
Record Creation date : Jul, 31 1998 Federal Motar Safety Number:
Defect Summary : Vehicle description: transit buses equipped with sunsource/fauver tandem hydraulic pumps. the hydraulic piston pump is driven by the engine and a shaft out of the back of the pump providing power to the power steering pump. the shafts are connected together with a coupling. this coupling is fitted with two retainer clips which keeps it centered between the two pumps. these buses were shipped missing the coupling retainer clips. Consequence Summary: Excessive movement of the coupling can disengage the two pump shafts, causing loss of power steering.
Corrective Summary : Dealers are inspecting and retrofitting the couplings on these pumps. Recall Notes: Owner notification has begun.all owners have been notified.
Manufacturer Supplied Component Description: Manufacturer Supplied Component Part Number: