EMERGENCY ONE / AMBULANCE / 1987
Components - Details | |
---|---|
NHTSA Record Id: 26333 | Vehicale/Equipment Name: EMERGENCY ONE |
Recalled Component Id: 000005361000056256000000096 | Manufacturer Supplied Component Name: |
Model Name: AMBULANCE | Model Year: 1987 |
NHTSA Campaign Number: 88V171000 | Mfr Campaign Number: |
Component Name: SERVICE BRAKES, AIR:SUPPLY:LOW PRESSURE WARNING:SWITCH | Manufacturer That Filed Report: E-ONE, INC. |
Start date of Manufacturing: Jan, 01 1977 | End date of Manufacturing: Jan, 01 1988 |
Report For : V | Potential Number Of Unit Affected: 71 |
Date Owner Notified By MFR : Dec, 07 1988 | Recall Initiator: ODI |
Manufacturers Of recalled Vehicles/Products : E-One Incorporated | Report Received Date: Nov, 01 1988 |
Record Creation date : Nov, 18 1988 | Federal Motar Safety Number: |
Defect Summary : Use of the air horn can cause the air pressure to drop below 85 psi. | Consequence Summary: If air pressure drops below 85 psi while the vehicle isbeing driven the rear brake spring chambers will start to apply causing therear brake drums to overheat. |
Corrective Summary : Install pressure protection valves in all air horn circuits. | Recall Notes: System: air pressure/brakes.vehicle information: ambulance units with rockwell u170 and s170 axles. |
Manufacturer Supplied Component Description: | Manufacturer Supplied Component Part Number: |