Components - Details
NHTSA Record Id: 26334 Vehicale/Equipment Name: EMERGENCY ONE
Recalled Component Id: 000005361000056255000000096 Manufacturer Supplied Component Name:
Model Name: AMBULANCE Model Year: 1984
NHTSA Campaign Number: 88V171000 Mfr Campaign Number:
Component Name: SERVICE BRAKES, AIR:SUPPLY:LOW PRESSURE WARNING:SWITCH Manufacturer That Filed Report: E-ONE, INC.
Start date of Manufacturing: Jan, 01 1977 End date of Manufacturing: Jan, 01 1988
Report For : V Potential Number Of Unit Affected: 71
Date Owner Notified By MFR : Dec, 07 1988 Recall Initiator: ODI
Manufacturers Of recalled Vehicles/Products : E-One Incorporated Report Received Date: Nov, 01 1988
Record Creation date : Nov, 18 1988 Federal Motar Safety Number:
Defect Summary : Use of the air horn can cause the air pressure to drop below 85 psi. Consequence Summary: If air pressure drops below 85 psi while the vehicle isbeing driven the rear brake spring chambers will start to apply causing therear brake drums to overheat.
Corrective Summary : Install pressure protection valves in all air horn circuits. Recall Notes: System: air pressure/brakes.vehicle information: ambulance units with rockwell u170 and s170 axles.
Manufacturer Supplied Component Description: Manufacturer Supplied Component Part Number: